Error Messages in Novell NetWare
ISDN-Controller B1 PCI v4.0 – 14 Troubleshooting 79
Error message: “Installation error, Controller-xx with I/O
address <xxx> does not answer.”
Possible cause: The ISDN-Controller was not fully loaded or
the hardware is damaged.
Remedy: Repeat the complete installation of the ISDN-Con-
troller. To test the hardware, you may install the ISDN Con-
troller in DOS and then run the program “B1 Test”. In case of
a hardware defect, please contact your dealer or AVM.
Error message: “... at least one application is registered.”
Possible cause: You tried to unload or uninstall the AVM
ISDN-Controller B1 PCI v4.0 while an application (such as a
terminal or fax program) was still using it.
Remedy: First end all applications that use the ISDN-Control-
ler. Then you can unload or uninstall it.
If the tips above have not helped you to solve your problem,
please contact AVM Support for further information (see the
section “Information, Updates and Support” on page 80).